A step up transformer is a critical device used in electrical power systems to increase voltage levels while decreasing current. This transformation is essential for efficient long-distance transmission of electricity, as higher voltages reduce energy loss due to resistance in the wires. In essence, the step up transformer allows for the effective transfer of power from generation facilities to substations.
| SC(B)10 | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC10-30 | 30 | 6,6.3,6.6,10,11/0.4 | 190 | 710 | 2.4 | 4.0 |
| SC10-50 | 50 | 6,6.3,6.6,10,11/0.4 | 270 | 1000 | 2.4 | 4.0 |
| SC10-80 | 80 | 6,6.3,6.6,10,11/0.4 | 370 | 1380 | 1.8 | 4.0 |
| SC10-100 | 100 | 6,6.3,6.6,10,11/0.4 | 400 | 1570 | 1.8 | 4.0 |
| SC10-125 | 125 | 6,6.3,6.6,10,11/0.4 | 470 | 1850 | 1.6 | 4.0 |
| SCB10-160 | 160 | 6,6.3,6.6,10,11/0.4 | 550 | 2130 | 1.6 | 4.0 |
| SCB10-200 | 200 | 6,6.3,6.6,10,11/0.4 | 630 | 2530 | 1.4 | 4.0 |
| SCB10-250 | 250 | 6,6.3,6.6,10,11/0.4 | 720 | 2760 | 1.4 | 4.0 |
| SCB10-315 | 315 | 6,6.3,6.6,10,11/0.4 | 880 | 3470 | 1.2 | 4.0 |
| SCB10-400 | 400 | 6,6.3,6.6,10,11/0.4 | 980 | 3990 | 1.2 | 4.0 |
| SCB10-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1160 | 4880 | 1.2 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1350 | 5880 | 1.0 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1300 | 5960 | 1.0 | 6.0 |
| SCB10-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1520 | 6960 | 1.0 | 6.0 |
| SCB10-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1770 | 8130 | 1.0 | 6.0 |
| SCB10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 2090 | 9690 | 1.0 | 6.0 |
| SCB10-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2450 | 11730 | 1.0 | 6.0 |
| SCB10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 3050 | 14450 | 0.8 | 6.0 |
| SCB10-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3600 | 17170 | 0.8 | 6.0 |
These transformers operate on the principle of electromagnetic induction, where the primary coil receives alternating current and creates a magnetic field. This magnetic field induces a higher voltage in the secondary coil, following the ratio of the number of turns in each coil. This process not only enhances voltage but also plays a vital role in ensuring the stability and reliability of the electrical grid.
Three Phase Transformer
A three phase transformer is designed to handle three-phase power systems, which are commonly used in industrial and commercial applications. This type of transformer can be configured in various ways, such as delta-delta, star-star, or a combination of both. Each configuration has its own advantages and is selected based on the specific requirements of the electrical system.
One of the primary benefits of three phase transformers is their ability to provide a more balanced load, which leads to improved efficiency and reduced losses. By distributing the load evenly across three phases, these transformers minimize the risk of overheating and enhance the overall performance of the power system. Moreover, they are often more compact than three single-phase transformers, making them a preferred choice for many applications.
China Manufacturing Company and ISO 9001

| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SCH15-30 | 30 | 6,6.3,6.6,10,11/0.4 | 70 | 710 | 1.6 | 4.0 |
| SCH15-50 | 50 | 6,6.3,6.6,10,11/0.4 | 90 | 1000 | 1.4 | 4.0 |
| SCH15-80 | 80 | 6,6.3,6.6,10,11/0.4 | 120 | 1380 | 1.3 | 4.0 |
| SCH15-100 | 100 | 6,6.3,6.6,10,11/0.4 | 130 | 1570 | 1.2 | 4.0 |
| SCH15-125 | 125 | 6,6.3,6.6,10,11/0.4 | 150 | 1850 | 1.1 | 4.0 |
| SC(B)H15-160 | 160 | 6,6.3,6.6,10,11/0.4 | 170 | 2130 | 1.1 | 4.0 |
| SC(B)H15-200 | 200 | 6,6.3,6.6,10,11/0.4 | 200 | 2530 | 1.0 | 4.0 |
| SC(B)H15-250 | 250 | 6,6.3,6.6,10,11/0.4 | 230 | 2760 | 1.0 | 4.0 |
| SC(B)H15-315 | 315 | 6,6.3,6.6,10,11/0.4 | 280 | 3470 | 0.9 | 4.0 |
| SC(B)H15-400 | 400 | 6,6.3,6.6,10,11/0.4 | 310 | 3990 | 0.8 | 4.0 |
| SC(B)H15-500 | 500 | 6,6.3,6.6,10,11/0.4 | 360 | 4880 | 0.8 | 4.0 |
| SC(B)H15-630 | 630 | 6,6.3,6.6,10,11/0.4 | 420 | 5880 | 0.7 | 4.0 |
| SC(B)H15-630 | 630 | 6,6.3,6.6,10,11/0.4 | 410 | 5960 | 0.7 | 6.0 |
| SC(B)H15-800 | 800 | 6,6.3,6.6,10,11/0.4 | 480 | 6960 | 0.7 | 6.0 |
| SC(B)H15-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 550 | 8130 | 0.6 | 6.0 |
| SC(B)H15-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 650 | 9690 | 0.6 | 6.0 |
| SC(B)H15-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 780 | 11730 | 0.6 | 6.0 |
| SC(B)H15-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 1000 | 14450 | 0.5 | 6.0 |
| SC(B)H15-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 1200 | 17170 | 0.5 | 6.0 |
In recent years, China has emerged as a leading manufacturer of electrical equipment, including transformers. Many companies in the region specialize in producing high-quality step up and three phase transformers that meet international standards. These manufacturers often invest significantly in advanced technology and skilled labor to ensure their products are reliable and efficient.
ISO 9001 certification is a vital aspect for companies looking to establish their credibility in the global market. This certification indicates that a manufacturing company adheres to strict quality management principles, ensuring consistent quality and customer satisfaction. By obtaining ISO 9001 certification, Chinese manufacturers of transformers demonstrate their commitment to excellence and their ability to compete on an international scale. This not only enhances their reputation but also instills confidence in customers looking for high-quality electrical solutions.