| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC10-800 | 800 | 33,35,38/6,6.3,6.6,10,11 | 2200 | 9400 | 1.1 | 6.0 |
| SC10-1000 | 1000 | Voltage combination(KV) | 2610 | 10800 | 1.1 | 6.0 |
| SC10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 3060 | 11900 | 1.0 | 6.0 |
| SC10-1500 | 1500 | Voltage combination(KV) | 3600 | 15400 | 1.0 | 6.0 |
| SC10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 4130 | 18200 | 0.9 | 7.0 |
| SC10-2500 | 2500 | Voltage combination(KV) | 4750 | 21800 | 0.9 | 7.0 |
| SC10-3150 | 3150 | 6,6.3,6.6,10,11/0.4 | 5880 | 24500 | 0.8 | 8.0 |
| SC10-4000 | 4000 | Voltage combination(KV) | 6860 | 29400 | 0.8 | 8.0 |
| SC10-5000 | 5000 | 6,6.3,6.6,10,11/0.4 | 8180 | 34960 | 0.7 | 8.0 |
| SC10-6300 | 6300 | Voltage combination(KV) | 9680 | 40800 | 0.7 | 8.0 |
| SC10-8000 | 8000 | 6,6.3,6.6,10,11/0.4 | 11000 | 46060 | 0.6 | 9.0 |
| SC10-10000 | 10000 | Voltage combination(KV) | 12660 | 56500 | 0.6 | 9.0 |
| SC10-12500 | 12500 | 6,6.3,6.6,10,11/0.4 | 15400 | 64600 | 0.5 | 9.0 |
| SC10-16000 | 16000 | Voltage combination(KV) | 18900 | 76000 | 0.5 | 9.0 |
| SC10-20000 | 20000 | 6,6.3,6.6,10,11/0.4 | 22400 | 85500 | 0.4 | 10.0 |
Power transformers are critical components in electrical power systems, facilitating the transmission of electricity over long distances. They are designed to step up or step down voltage levels, ensuring efficient energy distribution. With advancements in technology, modern power transformers are built to withstand varying operational conditions while maintaining reliability and performance.
In the manufacturing sector, China has emerged as a leading producer of power transformers. Chinese manufacturers leverage cutting-edge technologies and highly skilled labor to design and produce transformers that meet international standards. This has made them competitive in both domestic and global markets, catering to diverse customer needs.
Custom-made power transformers allow clients to specify their requirements regarding voltage, capacity, and design features. This flexibility is particularly beneficial for industries with unique operational demands, ensuring that the transformers can integrate seamlessly into existing systems. Moreover, custom solutions can enhance overall system efficiency and lifespan.
| Type | Rated capacity (KVA) | No-load losses(W) | Voltage combination (KV) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
| S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
| S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
| S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
| S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
| S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
| S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
| S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
| S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
| S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
| S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
| S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
| S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
| S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
| S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
| S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
| S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
| S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
| S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
| S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
| S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
| S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
| S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
| S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
| S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
| S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
| S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
| S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
| S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
| S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
| S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
| S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
| S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
| S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
| S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
| S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
Medium Voltage Transformers: A Key Component
Medium voltage transformers play a vital role in the distribution of electricity within urban and industrial settings. They are specifically designed to operate within a voltage range typically between 1 kV and 35 kV. Their primary function is to step down high voltage electricity from substations to levels suitable for commercial and residential use.

Manufacturers in China have also gained a reputation for producing high-quality medium voltage transformers. These devices are engineered to handle various loads and environmental conditions, ensuring they perform reliably in diverse applications. As industries evolve, the demand for efficient and durable medium voltage transformers continues to grow.
One of the significant advantages of medium voltage transformers is their ability to be customized according to specific project needs. By collaborating with manufacturers, clients can create tailored solutions that address their unique challenges, such as space constraints or specific load requirements. This customization is essential for optimizing performance and reducing operational costs.

The Role of Videos in Transformer Education
In today’s digital age, educational videos have become an invaluable resource for understanding complex equipment like power and medium voltage transformers. Manufacturers are increasingly utilizing video content to showcase their products, explain installation processes, and provide maintenance tips. These visual aids make it easier for customers to grasp the technicalities involved.
Chinese manufacturers often share videos that highlight their production processes and quality control measures. This transparency helps build trust with potential clients, demonstrating their commitment to delivering high-quality products. Furthermore, these videos can serve as a useful tool for training personnel on the correct handling and operation of transformers.
As the industry continues to evolve, incorporating multimedia resources like videos will likely become more prevalent. By engaging customers through informative content, manufacturers can enhance their marketing strategies while educating their audience about the importance and functionality of transformers. This approach not only promotes products but also fosters a deeper understanding of the technology involved.