Understanding Electrical Transformers
Electrical transformers are crucial devices in the power distribution system, designed to convert voltage from one level to another. They operate on the principle of electromagnetic induction, allowing for efficient transmission of electrical energy over long distances. The primary function of a transformer is to either step up or step down voltage levels, making them essential in various applications, from industrial settings to residential areas.

The efficiency and reliability of transformers are paramount, especially in large power systems. A well-designed transformer minimizes energy losses and ensures stable operation under varying loads. Factors such as core material, winding configuration, and insulation quality play significant roles in determining a transformer’s performance and longevity.
3150 kVA Transformer Specifications
| model | Rated power (KVA) | No-load losses(W) | Voltage combination (KV) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
| S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
| S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
| S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
| S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
| S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
| S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
| S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
| S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
| S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
| S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
| S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
| S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
| S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
| S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
| S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
| S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
| S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
| S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
| S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
| S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
| S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
| S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
| S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
| S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
| S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
| S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
| S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
| S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
| S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
| S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
| S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
| S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
| S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
| S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
| S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
A 3150 kVA transformer is a robust unit typically used in commercial and industrial settings. This rating indicates the transformer’s capacity to handle electrical loads effectively. With such capacity, it can support multiple systems simultaneously, ensuring that power distribution remains consistent and reliable.

This type of transformer is designed to accommodate high voltage levels while maintaining safety standards. It often features advanced cooling systems to dissipate heat generated during operation. Additionally, quality assurance processes, such as those mandated by ISO 9001, ensure that these transformers meet international standards for design and manufacturing.
Choosing a Reliable China Supplier
| Dry transformer 10 series | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit voltage (%) |
| SC10-30 | 30 | 6,6.3,6.6,10,11/0.4 | 190 | 710 | 2.4 | 4.0 |
| SC10-50 | 50 | 6,6.3,6.6,10,11/0.4 | 270 | 1000 | 2.4 | 4.0 |
| SC10-80 | 80 | 6,6.3,6.6,10,11/0.4 | 370 | 1380 | 1.8 | 4.0 |
| SC10-100 | 100 | 6,6.3,6.6,10,11/0.4 | 400 | 1570 | 1.8 | 4.0 |
| SC10-125 | 125 | 6,6.3,6.6,10,11/0.4 | 470 | 1850 | 1.6 | 4.0 |
| SCB10-160 | 160 | 6,6.3,6.6,10,11/0.4 | 550 | 2130 | 1.6 | 4.0 |
| SCB10-200 | 200 | 6,6.3,6.6,10,11/0.4 | 630 | 2530 | 1.4 | 4.0 |
| SCB10-250 | 250 | 6,6.3,6.6,10,11/0.4 | 720 | 2760 | 1.4 | 4.0 |
| SCB10-315 | 315 | 6,6.3,6.6,10,11/0.4 | 880 | 3470 | 1.2 | 4.0 |
| SCB10-400 | 400 | 6,6.3,6.6,10,11/0.4 | 980 | 3990 | 1.2 | 4.0 |
| SCB10-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1160 | 4880 | 1.2 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1350 | 5880 | 1.0 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1300 | 5960 | 1.0 | 6.0 |
| SCB10-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1520 | 6960 | 1.0 | 6.0 |
| SCB10-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1770 | 8130 | 1.0 | 6.0 |
| SCB10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 2090 | 9690 | 1.0 | 6.0 |
| SCB10-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2450 | 11730 | 1.0 | 6.0 |
| SCB10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 3050 | 14450 | 0.8 | 6.0 |
| SCB10-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3600 | 17170 | 0.8 | 6.0 |
When looking for a 3150 kVA transformer, partnering with a reputable supplier in China can offer numerous advantages. Many Chinese manufacturers adhere to strict quality control measures, often certified by ISO 9001, which guarantees that their products meet international quality standards.
Choosing a supplier with a solid track record helps ensure that you receive a reliable product that meets your specific needs. It’s essential to evaluate the supplier’s experience, customer reviews, and after-sales support, as these factors will significantly impact your overall satisfaction and operational efficiency.