Differences Between Dry Type and Oil Filled Transformers
Transformers are essential components in electrical systems, as they help to regulate voltage Levels and ensure the safe and efficient transmission of electricity. There are several types of transformers available on the market, each with its own unique characteristics and applications. Two common types of transformers are dry type transformers and oil-filled transformers. In this article, we will explore the differences between these two types of transformers and discuss their respective advantages and disadvantages.
Type | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09 |
SCH15-30 | 30 | 6,6.3,6.6,10,11/0.4 | 70 | 710 | 1.6 | 4.0 |
SCH15-50 | 50 | 6,6.3,6.6,10,11/0.4 | 90 | 1000 | 1.4 | 4.0 |
SCH15-80 | 80 | 6,6.3,6.6,10,11/0.4 | 120 | 1380 | 1.3 | 4.0 |
SCH15-100 | 100 | 6,6.3,6.6,10,11/0.4 | 130 | 1570 | 1.2 | 4.0 |
SCH15-125 | 125 | 6,6.3,6.6,10,11/0.4 | 150 | 1850 | 1.1 | 4.0 |
SC(B)H15-160 | 160 | 6,6.3,6.6,10,11/0.4 | 170 | 2130 | 1.1 | 4.0 |
SC(B)H15-200 | 200 | 6,6.3,6.6,10,11/0.4 | 200 | 2530 | 1.0 | 4.0 |
SC(B)H15-250 | 250 | 6,6.3,6.6,10,11/0.4 | 230 | 2760 | 1.0 | 4.0 |
SC(B)H15-315 | 315 | 6,6.3,6.6,10,11/0.4 | 280 | 3470 | 0.9 | 4.0 |
SC(B)H15-400 | 400 | 6,6.3,6.6,10,11/0.4 | 310 | 3990 | 0.8 | 4.0 |
SC(B)H15-500 | 500 | 6,6.3,6.6,10,11/0.4 | 360 | 4880 | 0.8 | 4.0 |
SC(B)H15-630 | 630 | 6,6.3,6.6,10,11/0.4 | 420 | 5880 | 0.7 | 4.0 |
SC(B)H15-630 | 630 | 6,6.3,6.6,10,11/0.4 | 410 | 5960 | 0.7 | 6.0 |
SC(B)H15-800 | 800 | 6,6.3,6.6,10,11/0.4 | 480 | 6960 | 0.7 | 6.0 |
SC(B)H15-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 550 | 8130 | 0.6 | 6.0 |
SC(B)H15-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 650 | 9690 | 0.6 | 6.0 |
SC(B)H15-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 780 | 11730 | 0.6 | 6.0 |
SC(B)H15-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 1000 | 14450 | 0.5 | 6.0 |
SC(B)H15-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 1200 | 17170 | 0.5 | 6.0 |
Dry type transformers, as the name suggests, do not use oil as a cooling medium. Instead, they rely on air or other gases to dissipate heat generated during operation. This makes them a popular choice for indoor applications where the use of oil may pose a fire hazard. Dry type transformers are also more environmentally friendly, as they do not require the use of oil, which can be harmful to the Environment if not properly disposed of.
On the other hand, oil-filled transformers use oil as a cooling medium to dissipate heat. The oil helps to transfer heat away from the transformer windings, ensuring that the transformer operates at a safe temperature. Oil-filled transformers are typically used in outdoor applications where the risk of fire is lower, such as in substations or power plants. However, the use of oil in these transformers can pose a risk of oil leaks or spills, which can be harmful to the environment if not properly contained.
One of the main differences between dry type and oil-filled transformers is their construction. Dry type transformers are typically smaller and lighter than oil-filled transformers, making them easier to transport and install. They also require less maintenance, as there is no need to monitor oil levels or perform regular oil testing. Oil-filled transformers, on the other hand, are larger and heavier due to the presence of oil. They also require regular maintenance to ensure that the oil is clean and free of contaminants.
In terms of cost, dry type transformers are generally more expensive than oil-filled transformers. This is due to the higher cost of materials used in their construction, as well as the additional Safety features required to prevent overheating. However, dry type transformers are more energy efficient than oil-filled transformers, which can Lead to long-term cost savings in terms of energy consumption.
When choosing between dry type and oil-filled transformers, it is important to consider the specific requirements of your application. If you need a transformer for indoor use or in a location where the risk of fire is high, a dry type transformer may be the best option. On the other hand, if you need a transformer for outdoor use or in a location where space is not an issue, an oil-filled transformer may be more suitable.
model | Rated\\u00a0power\\u00a0\\uff08KVA\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
In conclusion, both dry type and oil-filled transformers have their own unique advantages and disadvantages. It is important to carefully consider your specific requirements and budget constraints when choosing between these two types of transformers. By working with a reputable transformer specialist, such as China Enterprise, you can ensure that you get the right transformer for your needs at a discount. Be sure to check out their informative videos on transformer technology to learn more about the differences between dry type and oil-filled transformers.