Differences Between Dry Type and Oil Filled Transformers

Transformers are essential components in electrical systems, as they help to regulate voltage Levels and ensure the safe and efficient transmission of electricity. There are several types of transformers available on the market, each with its own unique characteristics and applications. Two common types of transformers are dry type transformers and oil-filled transformers. In this article, we will explore the differences between these two types of transformers and discuss their respective advantages and disadvantages.

Type Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 Voltage\\u00a0combination\\uff08KV\\uff09 Off-load\\u00a0losses\\uff08W\\uff09 Load\\u00a0losses\\uff08W\\uff09 Off-load\\u00a0current\\u00a0\\uff08%\\uff09 Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09
SCH15-30 30 6,6.3,6.6,10,11/0.4 70 710 1.6 4.0
SCH15-50 50 6,6.3,6.6,10,11/0.4 90 1000 1.4 4.0
SCH15-80 80 6,6.3,6.6,10,11/0.4 120 1380 1.3 4.0
SCH15-100 100 6,6.3,6.6,10,11/0.4 130 1570 1.2 4.0
SCH15-125 125 6,6.3,6.6,10,11/0.4 150 1850 1.1 4.0
SC(B)H15-160 160 6,6.3,6.6,10,11/0.4 170 2130 1.1 4.0
SC(B)H15-200 200 6,6.3,6.6,10,11/0.4 200 2530 1.0 4.0
SC(B)H15-250 250 6,6.3,6.6,10,11/0.4 230 2760 1.0 4.0
SC(B)H15-315 315 6,6.3,6.6,10,11/0.4 280 3470 0.9 4.0
SC(B)H15-400 400 6,6.3,6.6,10,11/0.4 310 3990 0.8 4.0
SC(B)H15-500 500 6,6.3,6.6,10,11/0.4 360 4880 0.8 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 420 5880 0.7 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 410 5960 0.7 6.0
SC(B)H15-800 800 6,6.3,6.6,10,11/0.4 480 6960 0.7 6.0
SC(B)H15-1000 1000 6,6.3,6.6,10,11/0.4 550 8130 0.6 6.0
SC(B)H15-1250 1250 6,6.3,6.6,10,11/0.4 650 9690 0.6 6.0
SC(B)H15-1600 1600 6,6.3,6.6,10,11/0.4 780 11730 0.6 6.0
SC(B)H15-2000 2000 6,6.3,6.6,10,11/0.4 1000 14450 0.5 6.0
SC(B)H15-2500 2500 6,6.3,6.6,10,11/0.4 1200 17170 0.5 6.0

Dry type transformers, as the name suggests, do not use oil as a cooling medium. Instead, they rely on air or other gases to dissipate heat generated during operation. This makes them a popular choice for indoor applications where the use of oil may pose a fire hazard. Dry type transformers are also more environmentally friendly, as they do not require the use of oil, which can be harmful to the Environment if not properly disposed of.

alt-813
On the other hand, oil-filled transformers use oil as a cooling medium to dissipate heat. The oil helps to transfer heat away from the transformer windings, ensuring that the transformer operates at a safe temperature. Oil-filled transformers are typically used in outdoor applications where the risk of fire is lower, such as in substations or power plants. However, the use of oil in these transformers can pose a risk of oil leaks or spills, which can be harmful to the environment if not properly contained.

One of the main differences between dry type and oil-filled transformers is their construction. Dry type transformers are typically smaller and lighter than oil-filled transformers, making them easier to transport and install. They also require less maintenance, as there is no need to monitor oil levels or perform regular oil testing. Oil-filled transformers, on the other hand, are larger and heavier due to the presence of oil. They also require regular maintenance to ensure that the oil is clean and free of contaminants.

In terms of cost, dry type transformers are generally more expensive than oil-filled transformers. This is due to the higher cost of materials used in their construction, as well as the additional Safety features required to prevent overheating. However, dry type transformers are more energy efficient than oil-filled transformers, which can Lead to long-term cost savings in terms of energy consumption.

alt-818

When choosing between dry type and oil-filled transformers, it is important to consider the specific requirements of your application. If you need a transformer for indoor use or in a location where the risk of fire is high, a dry type transformer may be the best option. On the other hand, if you need a transformer for outdoor use or in a location where space is not an issue, an oil-filled transformer may be more suitable.

model Rated\\u00a0power\\u00a0\\uff08KVA\\uff09 No-load\\u00a0losses\\uff08W\\uff09 Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 Load\\u00a0losses\\uff08W\\uff09 No-load\\u00a0current\\u00a0\\uff08%\\uff09 Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09
S11-M-30 30 100 6,6.3,10,10.5,11/0.4 600 2.3 4.0
S11-M-50 50 130 6,6.3,10,10.5,11/0.4 870 2.0 4.0
S11-M-63 63 150 6,6.3,10,10.5,11/0.4 1040 1.9 4.0
S11-M-80 80 180 6,6.3,10,10.5,11/0.4 1250 1.9 4.0
S11-M-100 100 200 6,6.3,10,10.5,11/0.4 1500 1.8 4.0
S11-M-125 125 240 6,6.3,10,10.5,11/0.4 1800 1.7 4.0
S11-M-160 160 280 6,6.3,10,10.5,11/0.4 2200 1.6 4.0
S11-M-200 200 340 6,6.3,10,10.5,11/0.4 2600 1.5 4.0
S11-M-250 250 400 6,6.3,10,10.5,11/0.4 3050 1.4 4.0
S11-M-315 315 480 6,6.3,10,10.5,11/0.4 3650 1.4 4.0
S11-M-400 400 570 6,6.3,10,10.5,11/0.4 4300 1.3 4.0
S11-M-500 500 680 6,6.3,10,10.5,11/0.4 5100 1.2 4.0
S11-M-630 630 810 6,6.3,10,10.5,11/0.4 6200 1.1 4.5
S11-M-800 800 980 6,6.3,10,10.5,11/0.4 7500 1.0 4.5
S11-M-1000 1000 1150 6,6.3,10,10.5,11/0.4 10300 1.0 4.5
S11-M-1250 1250 1360 6,6.3,10,10.5,11/0.4 12800 0.9 4.5
S11-M-1600 1600 1640 6,6.3,10,10.5,11/0.4 14500 0.8 4.5
S11-M-2000 2000 2280 6,6.3,10,10.5,11/0.4 17820 0.6 5.0
S11-M-2500 2500 2700 6,6.3,10,10.5,11/0.4 20700 0.6 5.0
S11-M-30- 30 90 20,22/0.4 660 2.1 5.5
S11-M-50- 50 130 20,22/0.4 960 2 5.5
S11-M-63- 63 150 20,22/0.4 1145 1.9 5.5
S11-M-80- 80 180 20,22/0.4 1370 1.8 5.5
S11-M-100- 100 200 20,22/0.4 1650 1.6 5.5
S11-M-125- 125 240 20,22/0.4 1980 1.5 5.5
S11-M-160- 160 290 20,22/0.4 2420 1.4 5.5
S11-M-200- 200 330 20,22/0.4 2860 1.3 5.5
S11-M-250- 250 400 20,22/0.4 3350 1.2 5.5
S11-M-315- 315 480 20,22/0.4 4010 1.1 5.5
S11-M-400- 400 570 20,22/0.4 4730 1 5.5
S11-M-500 500 680 20,22/0.4 5660 1 5.5
S11-M-630 630 810 20,22/0.4 6820 0.9 6
S11-M-800 800 980 20,22/0.4 8250 1.8 6
S11-M-1000 1000 1150 20,22/0.4 11330 0.7 6
S11-M-1250 1250 1350 20,22/0.4 13200 0.7 6
S11-M-1600 1600 1630 20,22/0.4 15950 0.6 6

In conclusion, both dry type and oil-filled transformers have their own unique advantages and disadvantages. It is important to carefully consider your specific requirements and budget constraints when choosing between these two types of transformers. By working with a reputable transformer specialist, such as China Enterprise, you can ensure that you get the right transformer for your needs at a discount. Be sure to check out their informative videos on transformer technology to learn more about the differences between dry type and oil-filled transformers.