Blog Topic: Differences Between Dry Type and Liquid Filled Transformers

Transformers are essential components in the electrical distribution system, responsible for stepping up or stepping Down voltage Levels to ensure efficient Power Transmission. There are two main types of transformers commonly used in the industry: dry type and liquid-filled transformers. Each type has its own set of advantages and disadvantages, making them suitable for different applications.

Dry type transformers, as the name suggests, do not use any liquid coolant for insulation. Instead, they rely on air or solid insulation materials to protect the windings from electrical faults. This makes them ideal for indoor installations where the risk of oil leakage is a concern. Dry type transformers are also more environmentally friendly as they do not pose a risk of contaminating the surrounding Environment in case of a leak.

alt-533
On the other hand, liquid-filled transformers use oil or other dielectric fluids as a coolant and insulating medium. These transformers are typically used in outdoor installations or in areas where space is not a constraint. Liquid-filled transformers are more efficient at dissipating heat generated during operation, making them suitable for high-power applications. However, they require regular maintenance to ensure the oil is clean and free from contaminants.

model Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 No-load\\u00a0losses\\uff08W\\uff09 Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 Load\\u00a0losses\\uff08W\\uff09 No-load\\u00a0current\\u00a0\\uff08%\\uff09 Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09
S11-M-30 30 100 6,6.3,10,10.5,11/0.4 600 2.3 4.0
S11-M-50 50 130 6,6.3,10,10.5,11/0.4 870 2.0 4.0
S11-M-63 63 150 6,6.3,10,10.5,11/0.4 1040 1.9 4.0
S11-M-80 80 180 6,6.3,10,10.5,11/0.4 1250 1.9 4.0
S11-M-100 100 200 6,6.3,10,10.5,11/0.4 1500 1.8 4.0
S11-M-125 125 240 6,6.3,10,10.5,11/0.4 1800 1.7 4.0
S11-M-160 160 280 6,6.3,10,10.5,11/0.4 2200 1.6 4.0
S11-M-200 200 340 6,6.3,10,10.5,11/0.4 2600 1.5 4.0
S11-M-250 250 400 6,6.3,10,10.5,11/0.4 3050 1.4 4.0
S11-M-315 315 480 6,6.3,10,10.5,11/0.4 3650 1.4 4.0
S11-M-400 400 570 6,6.3,10,10.5,11/0.4 4300 1.3 4.0
S11-M-500 500 680 6,6.3,10,10.5,11/0.4 5100 1.2 4.0
S11-M-630 630 810 6,6.3,10,10.5,11/0.4 6200 1.1 4.5
S11-M-800 800 980 6,6.3,10,10.5,11/0.4 7500 1.0 4.5
S11-M-1000 1000 1150 6,6.3,10,10.5,11/0.4 10300 1.0 4.5
S11-M-1250 1250 1360 6,6.3,10,10.5,11/0.4 12800 0.9 4.5
S11-M-1600 1600 1640 6,6.3,10,10.5,11/0.4 14500 0.8 4.5
S11-M-2000 2000 2280 6,6.3,10,10.5,11/0.4 17820 0.6 5.0
S11-M-2500 2500 2700 6,6.3,10,10.5,11/0.4 20700 0.6 5.0
S11-M-30- 30 90 20,22/0.4 660 2.1 5.5
S11-M-50- 50 130 20,22/0.4 960 2 5.5
S11-M-63- 63 150 20,22/0.4 1145 1.9 5.5
S11-M-80- 80 180 20,22/0.4 1370 1.8 5.5
S11-M-100- 100 200 20,22/0.4 1650 1.6 5.5
S11-M-125- 125 240 20,22/0.4 1980 1.5 5.5
S11-M-160- 160 290 20,22/0.4 2420 1.4 5.5
S11-M-200- 200 330 20,22/0.4 2860 1.3 5.5
S11-M-250- 250 400 20,22/0.4 3350 1.2 5.5
S11-M-315- 315 480 20,22/0.4 4010 1.1 5.5
S11-M-400- 400 570 20,22/0.4 4730 1 5.5
S11-M-500 500 680 20,22/0.4 5660 1 5.5
S11-M-630 630 810 20,22/0.4 6820 0.9 6
S11-M-800 800 980 20,22/0.4 8250 1.8 6
S11-M-1000 1000 1150 20,22/0.4 11330 0.7 6
S11-M-1250 1250 1350 20,22/0.4 13200 0.7 6
S11-M-1600 1600 1630 20,22/0.4 15950 0.6 6

When it comes to installation, dry type transformers are typically smaller and lighter than their liquid-filled counterparts. This makes them easier to transport and install, especially in areas where space is limited. Dry type transformers are also less prone to fire hazards, as they do not contain flammable liquids like oil. However, they may not be as efficient at dissipating heat as liquid-filled transformers, which can affect their overall performance.

Liquid-filled transformers, on the other hand, are more robust and durable, making them suitable for outdoor installations where they are exposed to harsh weather conditions. The oil coolant helps to dissipate heat more effectively, allowing the transformer to operate at higher power levels without overheating. However, the risk of oil leakage and the need for regular maintenance can be a drawback for some applications.

alt-538

Type Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 Voltage\\u00a0combination\\uff08KV\\uff09 Off-load\\u00a0losses\\uff08W\\uff09 Load\\u00a0losses\\uff08W\\uff09 Off-load\\u00a0Current\\u00a0(%) Short-circuit\\u00a0impedance\\u00a0(%)
SH15-M-30 30 6,6.3,10,10.5,11/0.4 33 630 1.50 4.0
SH15-M-50 50 6,6.3,10,10.5,11/0.4 43 910 1.20 4.0
SH15-M-63 63 6,6.3,10,10.5,11/0.4 50 1090 1.10 4.0
SH15-M-80 80 6,6.3,10,10.5,11/0.4 60 1310 1.00 4.0
SH15-M-100 100 6,6.3,10,10.5,11/0.4 75 1580 0.90 4.0
SH15-M-125 125 6,6.3,10,10.5,11/0.4 85 1890 0.80 4.0
SH15-M-160 160 6,6.3,10,10.5,11/0.4 100 2310 0.60 4.0
SH15-M-200 200 6,6.3,10,10.5,11/0.4 120 2730 0.60 4.0
SH15-M-250 250 6,6.3,10,10.5,11/0.4 140 3200 0.60 4.0
SH15-M-315 315 6,6.3,10,10.5,11/0.4 170 3830 0.50 4.0
SH15-M-400 400 6,6.3,10,10.5,11/0.4 200 4520 0.50 4.0
SH15-M-500 500 6,6.3,10,10.5,11/0.4 240 5140 0.50 4.0
SH15-M-630 630 6,6.3,10,10.5,11/0.4 320 6200 0.30 4.5
SH15-M-800 800 6,6.3,10,10.5,11/0.4 380 7500 0.30 4.5
SH15-M-1000 1000 6,6.3,10,10.5,11/0.4 450 10300 0.30 4.5
SH15-M-1250 1250 6,6.3,10,10.5,11/0.4 530 12000 0.20 4.5
SH15-M-1600 1600 6,6.3,10,10.5,11/0.4 630 14500 0.20 4.5
SH15-M-2000 2000 6,6.3,10,10.5,11/0.4 750 18300 0.20 5.0
SH15-M-2500 2500 6,6.3,10,10.5,11/0.4 900 21200 0.20 5.0

In China, there are many enterprises specializing in the manufacturing of both dry type and liquid-filled transformers. These companies have invested heavily in research and development to produce energy-saving transformers that meet the growing demand for efficient power distribution systems. By incorporating the latest technologies and materials, Chinese transformer manufacturers are able to produce high-quality products that are both reliable and cost-effective.

To showcase their expertise and capabilities, many Chinese transformer manufacturers have produced videos highlighting their manufacturing processes and testing procedures. These videos provide valuable insights into the design and production of transformers, giving customers a better understanding of the quality and reliability of the products. By leveraging digital marketing tools like videos, Chinese transformer manufacturers are able to reach a wider audience and showcase their products to potential customers around the world.

In conclusion, the choice between dry type and liquid-filled transformers depends on the specific requirements of the application. While dry type transformers are more suitable for indoor installations and where space is limited, liquid-filled transformers are better suited for outdoor installations and high-power applications. Chinese transformer manufacturers have made significant advancements in the design and production of both types of transformers, offering customers a wide range of options to choose from. By investing in energy-saving technologies and digital marketing strategies, Chinese transformer manufacturers are able to stay ahead of the competition and meet the growing demand for efficient power distribution systems.