Blog Topic: Differences Between Dry Type and Liquid Filled Transformers
Transformers are essential components in the electrical distribution system, responsible for stepping up or stepping Down voltage Levels to ensure efficient Power Transmission. There are two main types of transformers commonly used in the industry: dry type and liquid-filled transformers. Each type has its own set of advantages and disadvantages, making them suitable for different applications.
Dry type transformers, as the name suggests, do not use any liquid coolant for insulation. Instead, they rely on air or solid insulation materials to protect the windings from electrical faults. This makes them ideal for indoor installations where the risk of oil leakage is a concern. Dry type transformers are also more environmentally friendly as they do not pose a risk of contaminating the surrounding Environment in case of a leak.
On the other hand, liquid-filled transformers use oil or other dielectric fluids as a coolant and insulating medium. These transformers are typically used in outdoor installations or in areas where space is not a constraint. Liquid-filled transformers are more efficient at dissipating heat generated during operation, making them suitable for high-power applications. However, they require regular maintenance to ensure the oil is clean and free from contaminants.
model | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
When it comes to installation, dry type transformers are typically smaller and lighter than their liquid-filled counterparts. This makes them easier to transport and install, especially in areas where space is limited. Dry type transformers are also less prone to fire hazards, as they do not contain flammable liquids like oil. However, they may not be as efficient at dissipating heat as liquid-filled transformers, which can affect their overall performance.
Liquid-filled transformers, on the other hand, are more robust and durable, making them suitable for outdoor installations where they are exposed to harsh weather conditions. The oil coolant helps to dissipate heat more effectively, allowing the transformer to operate at higher power levels without overheating. However, the risk of oil leakage and the need for regular maintenance can be a drawback for some applications.
Type | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0Current\\u00a0(%) | Short-circuit\\u00a0impedance\\u00a0(%) |
SH15-M-30 | 30 | 6,6.3,10,10.5,11/0.4 | 33 | 630 | 1.50 | 4.0 |
SH15-M-50 | 50 | 6,6.3,10,10.5,11/0.4 | 43 | 910 | 1.20 | 4.0 |
SH15-M-63 | 63 | 6,6.3,10,10.5,11/0.4 | 50 | 1090 | 1.10 | 4.0 |
SH15-M-80 | 80 | 6,6.3,10,10.5,11/0.4 | 60 | 1310 | 1.00 | 4.0 |
SH15-M-100 | 100 | 6,6.3,10,10.5,11/0.4 | 75 | 1580 | 0.90 | 4.0 |
SH15-M-125 | 125 | 6,6.3,10,10.5,11/0.4 | 85 | 1890 | 0.80 | 4.0 |
SH15-M-160 | 160 | 6,6.3,10,10.5,11/0.4 | 100 | 2310 | 0.60 | 4.0 |
SH15-M-200 | 200 | 6,6.3,10,10.5,11/0.4 | 120 | 2730 | 0.60 | 4.0 |
SH15-M-250 | 250 | 6,6.3,10,10.5,11/0.4 | 140 | 3200 | 0.60 | 4.0 |
SH15-M-315 | 315 | 6,6.3,10,10.5,11/0.4 | 170 | 3830 | 0.50 | 4.0 |
SH15-M-400 | 400 | 6,6.3,10,10.5,11/0.4 | 200 | 4520 | 0.50 | 4.0 |
SH15-M-500 | 500 | 6,6.3,10,10.5,11/0.4 | 240 | 5140 | 0.50 | 4.0 |
SH15-M-630 | 630 | 6,6.3,10,10.5,11/0.4 | 320 | 6200 | 0.30 | 4.5 |
SH15-M-800 | 800 | 6,6.3,10,10.5,11/0.4 | 380 | 7500 | 0.30 | 4.5 |
SH15-M-1000 | 1000 | 6,6.3,10,10.5,11/0.4 | 450 | 10300 | 0.30 | 4.5 |
SH15-M-1250 | 1250 | 6,6.3,10,10.5,11/0.4 | 530 | 12000 | 0.20 | 4.5 |
SH15-M-1600 | 1600 | 6,6.3,10,10.5,11/0.4 | 630 | 14500 | 0.20 | 4.5 |
SH15-M-2000 | 2000 | 6,6.3,10,10.5,11/0.4 | 750 | 18300 | 0.20 | 5.0 |
SH15-M-2500 | 2500 | 6,6.3,10,10.5,11/0.4 | 900 | 21200 | 0.20 | 5.0 |
In China, there are many enterprises specializing in the manufacturing of both dry type and liquid-filled transformers. These companies have invested heavily in research and development to produce energy-saving transformers that meet the growing demand for efficient power distribution systems. By incorporating the latest technologies and materials, Chinese transformer manufacturers are able to produce high-quality products that are both reliable and cost-effective.
To showcase their expertise and capabilities, many Chinese transformer manufacturers have produced videos highlighting their manufacturing processes and testing procedures. These videos provide valuable insights into the design and production of transformers, giving customers a better understanding of the quality and reliability of the products. By leveraging digital marketing tools like videos, Chinese transformer manufacturers are able to reach a wider audience and showcase their products to potential customers around the world.
In conclusion, the choice between dry type and liquid-filled transformers depends on the specific requirements of the application. While dry type transformers are more suitable for indoor installations and where space is limited, liquid-filled transformers are better suited for outdoor installations and high-power applications. Chinese transformer manufacturers have made significant advancements in the design and production of both types of transformers, offering customers a wide range of options to choose from. By investing in energy-saving technologies and digital marketing strategies, Chinese transformer manufacturers are able to stay ahead of the competition and meet the growing demand for efficient power distribution systems.