Table of Contents
Overview of Distribution Transformers
Distribution transformers play a crucial role in the electrical power distribution system. They are responsible for stepping down high-voltage electricity from the transmission lines to lower voltages suitable for use in homes and businesses. A distribution transformer typically has a power rating ranging from a few kVA to several MVA, with 1600 kVA being a common size used in various applications.

These transformers are designed to operate at high efficiency and reliability, ensuring that electricity is delivered consistently to end-users. The construction of a distribution transformer involves high-quality materials and advanced engineering techniques to withstand environmental factors, making them essential for urban and rural electrical networks.

1600 kVA Transformer Specifications
A 1600 kVA transformer is commonly used in industrial and commercial settings where significant amounts of power are required. This type of transformer is capable of supplying power to multiple loads simultaneously, making it ideal for factories, schools, and large buildings. The design ensures optimal performance with minimal energy losses, which is vital for cost-effective operations.
| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC12-30 | 30 | 6,6.3,6.6,10,11/0.4 | 150 | 710 | 2.0 | 4.0 |
| SC12-50 | 50 | 6,6.3,6.6,10,11/0.4 | 215 | 1000 | 2.0 | 4.0 |
| SC12-80 | 80 | 6,6.3,6.6,10,11/0.4 | 295 | 1380 | 1.5 | 4.0 |
| SC12-100 | 100 | 6,6.3,6.6,10,11/0.4 | 320 | 1570 | 1.5 | 4.0 |
| SC12-125 | 125 | 6,6.3,6.6,10,11/0.4 | 375 | 1850 | 1.3 | 4.0 |
| SCB12-160 | 160 | 6,6.3,6.6,10,11/0.4 | 430 | 2130 | 1.3 | 4.0 |
| SCB12-200 | 200 | 6,6.3,6.6,10,11/0.4 | 495 | 2530 | 1.1 | 4.0 |
| SCB12-250 | 250 | 6,6.3,6.6,10,11/0.4 | 575 | 2760 | 1.1 | 4.0 |
| SCB12-315 | 315 | 6,6.3,6.6,10,11/0.4 | 705 | 3470 | 1.0 | 4.0 |
| SCB12-400 | 400 | 6,6.3,6.6,10,11/0.4 | 785 | 3990 | 1.0 | 4.0 |
| SCB12-500 | 500 | 6,6.3,6.6,10,11/0.4 | 930 | 4880 | 1.0 | 4.0 |
| SCB12-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1070 | 5880 | 0.85 | 4.0 |
| SCB12-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1040 | 5960 | 0.85 | 6.0 |
| SCB12-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1210 | 6960 | 0.85 | 6.0 |
| SCB12-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1410 | 8130 | 0.85 | 6.0 |
| SCB12-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 1670 | 9690 | 0.85 | 6.0 |
| SCB12-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 1960 | 11700 | 0.85 | 6.0 |
| SCB12-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 2440 | 14400 | 0.7 | 6.0 |
| SCB12-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 2880 | 17100 | 0.7 | 6.0 |
The technical specifications of a 1600 kVA transformer include its voltage ratings, impedance, and cooling methods. Most of these transformers are oil-immersed, providing excellent cooling capabilities and durability. They are also equipped with safety features to protect against overloads and short circuits, thereby enhancing their operational security.
| SC(B)11 | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| SC11-30 | 30 | 6,6.3,6.6,10,11/0.4 | 180 | 710 | 2.4 | 4.0 |
| SC11-50 | 50 | 6,6.3,6.6,10,11/0.4 | 250 | 1000 | 2.4 | 4.0 |
| SC11-80 | 80 | 6,6.3,6.6,10,11/0.4 | 340 | 1380 | 1.8 | 4.0 |
| SC11-100 | 100 | 6,6.3,6.6,10,11/0.4 | 360 | 1570 | 1.8 | 4.0 |
| SC11-125 | 125 | 6,6.3,6.6,10,11/0.4 | 420 | 1850 | 1.6 | 4.0 |
| SCB11-160 | 160 | 6,6.3,6.6,10,11/0.4 | 490 | 2130 | 1.6 | 4.0 |
| SCB11-200 | 200 | 6,6.3,6.6,10,11/0.4 | 560 | 2530 | 1.4 | 4.0 |
| SCB11-250 | 250 | 6,6.3,6.6,10,11/0.4 | 650 | 2760 | 1.4 | 4.0 |
| SCB11-315 | 315 | 6,6.3,6.6,10,11/0.4 | 790 | 3470 | 1.2 | 4.0 |
| SCB11-400 | 400 | 6,6.3,6.6,10,11/0.4 | 880 | 3990 | 1.2 | 4.0 |
| SCB11-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1050 | 4880 | 1.2 | 4.0 |
| SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1210 | 5880 | 1.0 | 4.0 |
| SCB11-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1170 | 5960 | 1.0 | 6.0 |
| SCB11-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1370 | 6960 | 1.0 | 6.0 |
| SCB11-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1590 | 8130 | 1.0 | 6.0 |
| SCB11-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 1880 | 9690 | 1.0 | 6.0 |
| SCB11-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2210 | 11730 | 1.0 | 6.0 |
| SCB11-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 2720 | 14450 | 0.8 | 6.0 |
| SCB11-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3200 | 17170 | 0.8 | 6.0 |
Manufacturing Standards in China
China’s manufacturing industry is known for producing a wide range of electrical equipment, including distribution transformers. Factories in China that produce 1600 kVA transformers often adhere to international standards like ISO 9001, which focuses on quality management systems. This certification ensures that products meet customer requirements and regulatory standards consistently.
By implementing ISO 9001 practices, manufacturers in China can enhance their production processes, reduce waste, and improve product quality. This has led to an increase in the global competitiveness of Chinese-made transformers, making them a preferred choice for businesses seeking reliable and efficient electrical solutions. The emphasis on quality controls also helps in minimizing defects, thus ensuring that customers receive durable products.